KX8 CCA

KX8 CCA

KX8 CCA

KX8 CCA

Application: 
This cable is used for signal transmissions, in analogical video and Video 
surveillance applications.Fixed and Mobile installations.
Center Conductor:
Copper Clad Steel 
Nominal Diameter: 7 x 0.40mm 17 AWG
Dielectric: 
Solid Polyethylene 
Nominal Diameter: 7.25mm 0.825”
Shield: 
CCA Braid: 83% Coverage
Jacket: 
Green PVC 
Nominal Diameter of Cable: 10.3mm 0.405” 
Weight: 122kg/km 182 lbs/1000ft
Electrical Properties 
Impedance @ 200MHz: 75 Ω +/- 3 
Nominal Capacitance: 67 pF/m 20.5 pF/Ft 
Velocity of Propagation: 66% 
Conductor Resistance:   Inner 22.2 Ω/km 6.8 Ω/1000Ft   Outer 16.5 Ω/km 5.0 Ω/1000Ft

 Attenuation: @ 20°C /@ 68°F 
@ Frequencies MHz                      dB/100m                        dB/100ft 
10                                                                    2.9                                        0.9 
200                                                              10.9                                        3.3 
1000                                                          27.5                                         8.4